Product Identification

Product ID:IC 531, PART 2
MSDS Date:01/23/1986
FSC:8010
NIIN:00N009001
MSDS Number: BCRLP

Responsible Party
INORGANIC COATINGS,INC.
5 GREAT VALLEY PARKWAY,SUITE 317
MALVERN, PA 19355
US

Emergency Phone: 215-640-2880

Info Phone: 215-640-2880

Cage: INORG

Contractor
INORGANIC COATINGS,INC.
MALVERN, PA 19355 US

Telephone: 215-648-3990

Cage: INORG

Ingredients

ZINC (SARA III)

CAS: 7440-66-6

RTECS: ZG8600000

OSHA PEL 10 MG ZNO/M3

ACGIH TLV: 10 MG ZNO/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:N/K
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS OF OVEREXPOSURE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION:FRESHLY FORMED ZINC OXIDE FUME MAY
CAUSE "METAL FUME FEVER" WITH FLU-LIKE SYMPTOMS OF FEVER AND
CHILLS.SYMPTOMS USUALLY DISAPPEAR IN 24-48 HRS.EYES AND
SKIN:CONTACT WITH FINELY DIVIDED PART ICULATE MATTER MAY CAUSE
MECHANICAL IRRITATION.INGESTION:N/K .
Medical Cond Aggravated by Exposure:N/K

First Aid

First Aid:SKIN:REMOVE CONTAMINATED CLOTHING.WASH AFFECTED AREA
THOROUGHLY.GET MEDICAL ATTENTION.EYES:FLUSH WITH PLENTY OF WATER
FOR AT LEAST 15 MIN.GET MEDICAL ATTENTION.INHALATION:REMOVE TO
FRESH AIR.SUPPORT B REATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION)
.GET MED ATTN.INGEST:GET MED ATTN IMMEDIATELY

Fire Fighting

Flash Point:N/K
Lower Limits:0.55 OZ/CUF
Extinguishing Media:CLASS D,DRY POWDER FIRE EXTINGUISHER,DRY SAND,ZINC
OXIDE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROT EQUIP
.DO NOT USE H*2O.COVER ALL OPEN ZINC DUST CONTAINERS.DO NOT SPREAD
OUT MATERIALS.
Unusual Fire/Explosion Hazard:WATER WILL REACT WITH HOT DUST TO FORM
HYDROGEN,AN EXPLOSIVE GAS.IGNITION TEMP OF DUST
CLOUD:700-760F,371-404C.

Accidental Release

Spill Release Procedures:CLEAN UP IMMEDIATELY BY SWEEPING OR
SHOVELING.FOLLOW UP WITH VACUUMING.FLUSH AREA THOROUGHLY.BAN
SMOKING AND OPEN FLAME DURING CLEAN-UP. AVOID SPARKS.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:ZINC DUST SHOULD BE STORED COVERED IN
A COOL,DRY,WELL-VENTILATED AREA.
Other Precautions:HOT DUST MAY REACT WITH WATER TO FORM HYDROGEN.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .NIOSH APPROVED DUST-MIST-FUME RESPIRATOR(MFR).
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .VENTILATION NOT USUALLY REQUIRED
Protective Gloves:MAY HELP PREVENT SKIN IRRITATION.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:BARRIER CREAMS MAY HELP PREVENT SKIN
IRRITATION.
Work Hygienic Practices:N/K
Supplemental Safety and Health
N/K

Chemical Properties

Boiling Pt:B.P. Text:1665F,907C
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Spec Gravity:7.14 (WATER=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:DARK BLUE-GRAY POWDER

Stability

Stability Indicator/Materials to Avoid:YES
WATER,ACIDS,ALKALIS.
Stability Condition to Avoid:HIGH HUMIDITY,WATER.
Hazardous Decomposition Products:NONE,BUT DUST MAY REACT WITH WATER TO
FORM HYDROGEN.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE & LOCAL REGULATIONS .DISPOSE OF IN DRY,CLOSED
CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.